Dongfeng Duolica 12000L water sprinkler truck configuration and use essentials

Dongfeng Duolica 12000L water sprinkler truck
Dongfeng Duolica 12000L water sprinkler truck

Dongfeng Duolica 12000L water sprinkler truck top-mounted configuration: the tank is made of 4mm-thick WISCO high-quality carbon steel plate, with a volume of 12 cubic meters, front flushing (spraying) and rear sprinkling, with side spray, with a working platform at the back of the tank, and installation on the platform Green sprinkler cannons.

Dongfeng 12000L water sprinkler truck
Dongfeng 12000L water sprinkler truck

Dongfeng Duolica 12000L water sprinkler truck can be rotated in all directions, can be continuously adjusted to direct, heavy rain, light rain, drizzle, with safety guardrail, equipped with Hangzhou Weilong high-power special sprinkler pump, the pump can be self-priming and self-draining, install a filter, with a fire interface, Water can be fed through a fire hydrant, with a self-flow valve, and an optional 20-meter greening reel with the car, which can be sprayed with pesticides and can body metal paint.

12000 liters water sprinkler truck
12000 liters water sprinkler truck

Users can choose to install high-power fire-fighting water pumps, which can be used as fire-fighting sprinklers in emergency. Chassis configuration: Chassis model: EQ1185LJ9CDE, 3590 wheelbase (optional 4500 wheelbase), Cummins 170 horsepower engine, Fast 6-gear box, Dana rear axle, with original air conditioning, electric doors and windows, central locking, 295 tubeless tires .

12000L water  truck
12000L water truck

Precautions for the use of Dongfeng Duolica 12000L water sprinkler truck:

  1. When the sprinkler uses river ditches and ponds as water sources, pay attention to all the ends of the suction pipes are submerged in the water. In order to avoid inhaling rocks or more mud, sand, and floating debris, the end of the suction pipe is generally equipped with a filter device. It is strictly forbidden to remove the filter device when absorbing water.
    If the water source is shallow, you need to dig deeper at the suction point in advance to ensure that it does not contain debris and air.
    Water pumps of different sprinklers have different requirements for the water source. The pumps of the sprinklers have different requirements for the water source. The clean water pump requires no impurities in the water, and the turbid water pump requires no stones and excessive sand in the water. .
  2. When the self-priming water pump is used for the first time, water diversion is required, and there is no need to add water diversion in the future.
  3. The inlet pipe system must maintain a certain degree of vacuum when sucking water in order to suck water into the tank. The water inlet pipe system must be sealed and reliable, the hose must not be damaged, and the hard pipe must not have cracks, otherwise air leakage will occur and the water cannot be sucked.
  4. The gear shifting of the power take-off device must be carried out when the sprinkler is stopped, whether it is before absorbing water or before sprinkling water.
  5. Before winter comes, the water in the water pump and the water pipe should be emptied to prevent freezing and cracking. In northern China, there is generally no construction in severe winter, so immediately after the completion of the construction, the water in the pump and the water pipe is immediately drained to prevent future troubles.